AJP - GI Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Gastrointest Liver Physiol 265: G587-G594, 1993;
0193-1857/93 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Harringer, W.
Right arrow Articles by Vlahakes, G. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Harringer, W.
Right arrow Articles by Vlahakes, G. J.

AJP - Gastrointestinal and Liver Physiology, Vol 265, Issue 3 587-G594, Copyright © 1993 by American Physiological Society


ARTICLES

Evaluation and validation of microsphere technique for determination of pancreatic blood flow

W. Harringer, C. Fernandez-del Castillo, D. W. Rattner, J. L. Guerrero, A. L. Warshaw and G. J. Vlahakes
Department of Surgery, Harvard Medical School, Boston, Massachusetts.

The purpose of this study was to evaluate the radiolabeled microsphere technique for pancreatic blood flow measurements. Using a canine model with an isolated pancreatic circulation, we assessed the shunting of 11- and 15-microns-diam microspheres in the pancreas, correlated pancreatic blood flow measurements obtained with the microsphere technique with those made with an ultrasonic flow probe, and determined the effects of high doses of microspheres on pancreatic blood flow and its measurement. Microspheres of 11 microns demonstrate significant shunting through the pancreatic microcirculation with underestimation of pancreatic blood flow of approximately 10% compared with results obtained with 15-microns microspheres. There is a close linear relationship between flow results obtained with 15-microns microspheres and with an ultrasonic flow probe for both the resting (r = 0.85) and the secretin-stimulated pancreas (r = 0.97). Left atrial injections of very large doses of 15-microns microspheres (50 x 10(6)) caused an acute transient reduction of pancreatic blood flow (to 39% of baseline flow) with a return to baseline values within 2 min. The accuracy of flow results and absence of physiological changes after repeated injections support the use of 15-microns microspheres for pancreatic blood flow measurements.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
A. J. Fischman, H. Hsu, E. A. Carter, Y. M. Yu, R. G. Tompkins, J. L. Guerrero, V. R. Young, and N. M. Alpert
Regional measurement of canine skeletal muscle blood flow by positron emission tomography with H215O
J Appl Physiol, April 1, 2002; 92(4): 1709 - 1716.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
N. Veal, F. Moal, J. Wang, E. Vuillemin, F. Oberti, E. Roy, M. Kaassis, R. Trouve, J.-L. Saumet, and P. Cales
New method of cardiac output measurement using ultrasound velocity dilution in rats
J Appl Physiol, September 1, 2001; 91(3): 1274 - 1282.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online