AJP - GI AJP: Heart and Circulatory Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Gastrointest Liver Physiol 282: G785-G793, 2002; doi:10.1152/ajpgi.00394.2001
0193-1857/02 $5.00
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via ISI Web of Science (14)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Takeda, T.
Right arrow Articles by Mittal, R. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Takeda, T.
Right arrow Articles by Mittal, R. K.
Vol. 282, Issue 5, G785-G793, May 2002

A novel ultrasound technique to study the biomechanics of the human esophagus in vivo

Torahiko Takeda1, Ghassan Kassab2, Jianmin Liu1, James L. Puckett1, Rishi R. Mittal1, and Ravinder K. Mittal1

1 Division of Gastroenterology, Veterans Affairs Medical Center, University of California, San Diego, 92161; and 2 Center for Biomedical Engineering, University of California, Irvine, California 92697

The objectives of this study were to validate a novel ultrasound technique and to use it to study the circumferential stress-strain properties of the human esophagus in vivo. A manometric catheter equipped with a high-compliance bag and a high-frequency intraluminal ultrasonography probe was used to record esophageal pressure and images. Validation studies were performed in vitro followed by in vivo studies in healthy human subjects. Esophageal distensions were performed with either an isovolumic (5-20 ml of water) or with an isobaric (10-60 mmHg) technique. Sustained distension was also performed for 3 min in each subject. The circumferential wall stress and strain were calculated. In vitro studies indicate that the ultrasound technique can make measurements of the esophageal wall with an accuracy of 0.01 mm. The in vivo studies provide the necessary data to compute the Kirchhoff's stress, Green's strain, and Young's elastic modulus during esophageal distensions. The stress-strain relationship revealed a linear shape, the slope of which corresponds to the Young's modulus. During sustained distensions, we found dynamic changes of stress and strain during the period of distension. We describe and validate a novel ultrasound technique that allows measurement of biomechanical properties of the esophagus in vivo in humans.

Kirchhoff's stress; Green's strain; Young's modulus