AJP - GI Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Gastrointest Liver Physiol 292: G377-G384, 2007. First published August 31, 2006; doi:10.1152/ajpgi.00311.2006
0193-1857/07 $8.00
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
292/1/G377    most recent
00311.2006v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (3)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by McMahon, B. P.
Right arrow Articles by Gregersen, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by McMahon, B. P.
Right arrow Articles by Gregersen, H.

NEUROREGULATION AND MOTILITY

The functional lumen imaging probe (FLIP) for evaluation of the esophagogastric junction

Barry P. McMahon,1 Jens B. Frøkjær,1 Peter Kunwald,2 Donghua Liao,1 Peter Funch-Jensen,3 Asbjørn M. Drewes,1,2 and Hans Gregersen1,2

1Centre for Visceral Biomechanics and Pain, Aalborg Hospital and 2Centre for Sensory Motor Interaction, Department of Health Science and Technology, Aalborg University, Aalborg, Denmark; and 3Department of Surgical Gastroenterology L, Aarhus University Hospital, Aarhus, Denmark

Submitted 14 July 2006 ; accepted in final form 29 August 2006

There is a need for new methods to study the dynamics of the esophagogastric junction (EGJ). The aims were to verify the efficacy and usefulness of a "functional lumen imaging probe" (FLIP) for the evaluation of the EGJ. Eight healthy volunteers (6 men), median age 26 (21–35) yr, and two achalasia patients underwent the FLIP procedure. The EGJ was located by manometry. The FLIP measured eight cross-sectional areas (CSAs) 4 mm apart together with the pressure inside a saline-filled cylindrical bag. The data showed the geometric profile of the EGJ reconstructed in a video animation of its dynamic activity. A plot of curve-fitted data for the smallest CSA vs. pressure after balloon distension indicated that the pressure increased from 18 cmH2O at a CSA of 38 mm2 to a pressure of 37 cmH2O at a CSA of 230 mm2 for the healthy controls. In one achalasia patient (unsuccessfully treated with dilations), the CSA never rose above the minimal measurable value despite the pressure increasing to 50 cmH2O. In another achalasia patient (successfully treated with dilations), the pressure only reached 15 cmH2O despite opening to a CSA of 250 mm2. In conclusion, FLIP represents the first dynamic technique to profile the function and anatomy of the EGJ. The method can be used practically to evaluate difficult cases of EGJ dysfunction and may provide a role in evaluating patients before and after therapies for diseases affecting the EGJ such as achalasia and gastroesophageal reflux disease.

esophagus; competence; distensibility; cross-sectional area; functional imaging



Address for reprint requests and other correspondence: B. McMahon, Medical Physics & Clinical Engineering, Adelaide & Meath Hospital, Tallaght, Dublin 24, Ireland (e-mail: barry{at}mech-sense.com)




This article has been cited by other articles:


Home page
SURG INNOVHome page
B. P. McMahon, D. O'Donovan, Donghua Liao, Jingbo Zhao, R. Schiretz, R. Heninrich, and H. Gregersen
Analysis of Abdominal Wounds Made by Surgical Trocars Using Functional Luminal Imaging Probe (FLIP) Technology
Surgical Innovation, September 1, 2008; 15(3): 208 - 212.
[Abstract] [PDF]