AJP - GI Watch the video to learn how APS reaches out to developing nations.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Gastrointest Liver Physiol 296: G709-G716, 2009. First published December 18, 2008; doi:10.1152/ajpgi.90318.2008
0193-1857/09 $8.00
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
296/4/G709    most recent
90318.2008v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hocke, M.
Right arrow Articles by Stallmach, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hocke, M.
Right arrow Articles by Stallmach, A.

NEUROREGULATION AND MOTILITY

Every slow-wave impulse is associated with motor activity of the human stomach

Michael Hocke,1 Ulrike Schöne,1 Hendryk Richert,2 Peter Görnert,2 Jutta Keller,3 Peter Layer,3 and Andreas Stallmach1

1Clinic of Internal Medicine II, Department of Gastroenterology, Hepatology and Infectious Diseases, Friedrich Schiller University Jena, 2Innovent Jena, Germany; and 3Israelitic Hospital, Academic Hospital University of Hamburg, Hamburg, Germany

Submitted 2 May 2008 ; accepted in final form 8 December 2008

Using a newly developed high-resolution three-dimensional magnetic detector system (3D-MAGMA), we observed periodical movements of a small magnetic marker in the human stomach at the typical gastric slow-wave frequency, that is 3 min–1. Thus we hypothesized that each gastric slow wave induces a motor response that is not strong enough to be detected by conventional methods. Electrogastrographies (EGG, Medtronic, Minneapolis, MN) for measurement of gastric slow waves and 3D-MAGMA (Innovent, Jena, Germany) measurements were simultaneously performed in 21 healthy volunteers (10 men, 40.4 ± 13.6 yr; 11 women, 35.8 ± 11.6 yr). The 3D-MAGMA system contains 27 highly sensitive magnetic field sensors that are able to locate a magnetic pill inside a human body with an accuracy of ±5 mm or less in position and ±2° in orientation at a frequency of 50 Hz. Gastric transit time of the magnetic marker ranged from 19 to 154 min. The mean dominant EGG frequency while the marker was in the stomach was 2.87 ± 0.15 cpm. The mean dominant 3D-MAGMA frequency during this interval was nearly identical; that is, 2.85 ± 0.15 movements per minute. We observed a strong linear correlation between individual dominant EGG and 3D-MAGMA frequency (R = 0.66, P = 0.0011). Our findings suggest that each gastric slow wave induces a minute contraction that is too small to be detected by conventional motility investigations but can be recorded by the 3D-MAGMA system. The present slow-wave theory that assumes that the slow wave is a pure electrical signal should be reconsidered.

electrogastrography; pacemaker; magnetic marker; magnetic monitoring; 3D-MAGMA



Address for reprint requests and other correspondence: M. Hocke, Clinic of Internal Medicine II, Dept. of Gastroenterology, Hepatology and Infectious Diseases, Friedrich-Schiller-Univ. Jena, Erlanger Allee 101, D-07747 Jena, Germany (e-mail: michael.hocke{at}klinikum-meiningen.de)







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online
Copyright © 2009 by the American Physiological Society.